<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Blog :: Mezintel Inc. - Measurements Intelligence &#187; MWD &#8211; Depth Tracking</title>
	<atom:link href="https://www.mezintel.com/blog/category/mwd-depth-tracking/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.mezintel.com/blog</link>
	<description></description>
	<lastBuildDate>Mon, 26 May 2025 17:05:38 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.5.2</generator>
		<item>
		<title>MWD Communication via Ethernet or Serial Port</title>
		<link>https://www.mezintel.com/blog/mwd-logging-via-ethernet-or-serial-port/</link>
		<comments>https://www.mezintel.com/blog/mwd-logging-via-ethernet-or-serial-port/#comments</comments>
		<pubDate>Fri, 09 Aug 2019 19:00:03 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[Latest Features]]></category>
		<category><![CDATA[MWD - Depth Tracking]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>
		<category><![CDATA[communication]]></category>
		<category><![CDATA[depth]]></category>
		<category><![CDATA[serial port]]></category>
		<category><![CDATA[tip]]></category>
		<category><![CDATA[v. 22.15.127]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=2909</guid>
		<description><![CDATA[<p>You can connect Mezintel Gamma to EDR depth tracking systems or MWD decoding systems via two modes: Serial Port (i.e. COM Port Number &#038; Baud Rate) Ethernet (i.e. IP Address and Telnet Port Number) These two methods are made available to guarantee that a PC running Mezintel Gamma LWD/MWD software (version 22.15.127 onwards), can connect [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/mwd-logging-via-ethernet-or-serial-port/">MWD Communication via Ethernet or Serial Port</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/mwd-logging-via-ethernet-or-serial-port/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Quickly Re-Calibrate Mezintel Depth Tracking System</title>
		<link>https://www.mezintel.com/blog/recalibrating-mezintel-depth-tracker/</link>
		<comments>https://www.mezintel.com/blog/recalibrating-mezintel-depth-tracker/#comments</comments>
		<pubDate>Sat, 04 Aug 2018 21:56:31 +0000</pubDate>
		<dc:creator>Anthony Lukindo</dc:creator>
				<category><![CDATA[Latest Features]]></category>
		<category><![CDATA[MWD - Depth Tracking]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=2528</guid>
		<description><![CDATA[<p>Power outage incidents, while rare, do occur causing interruption of drilling rig sites operations and services. Mezintel Depth tracking systems have been subject to such scenarios resulting in lost connectivity and lost calibration. However, once power returns, there is a way to quickly recover saved calibration table and Here&#8217;s how to do that: STEP 1: [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/recalibrating-mezintel-depth-tracker/">Quickly Re-Calibrate Mezintel Depth Tracking System</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/recalibrating-mezintel-depth-tracker/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>WITS Simulator for Drilling Depth Data</title>
		<link>https://www.mezintel.com/blog/edr-wits-simulator/</link>
		<comments>https://www.mezintel.com/blog/edr-wits-simulator/#comments</comments>
		<pubDate>Fri, 21 Jul 2017 22:39:15 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[MWD - Depth Tracking]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>
		<category><![CDATA[serial port]]></category>
		<category><![CDATA[technical support]]></category>
		<category><![CDATA[tip]]></category>
		<category><![CDATA[troubleshooting]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=2115</guid>
		<description><![CDATA[<p>Often MWD operators and tool engineers need to simulate WITS data for depth. Depth simulation may be needed for training or shop testing where a depth tracking system (DTS) is not available, or for troubleshooting communication with a present DTS or EDR. Mezintel Gamma software offers in-app simulation for both MWD and depth data, and [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/edr-wits-simulator/">WITS Simulator for Drilling Depth Data</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/edr-wits-simulator/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>User Guides</title>
		<link>https://www.mezintel.com/blog/user-guides/</link>
		<comments>https://www.mezintel.com/blog/user-guides/#comments</comments>
		<pubDate>Thu, 31 Dec 2015 12:50:01 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[Construction Materials Testing]]></category>
		<category><![CDATA[MWD - Depth Tracking]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=1595</guid>
		<description><![CDATA[<p>Mezintel Gamma User Manual version 22.00 &#8211; current revision Mezintel Depth Tracker User Manual version 4.14 &#8211; current revision What makes up a depth tracking system Tips on using MWD depth tracking sensors Mezintel BreakTest User Manual version 15.09 &#8211; current revision</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/user-guides/">User Guides</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/user-guides/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>WITS Format as used by Mezintel MWD Products</title>
		<link>https://www.mezintel.com/blog/wits-format-mezintel-mwd/</link>
		<comments>https://www.mezintel.com/blog/wits-format-mezintel-mwd/#comments</comments>
		<pubDate>Wed, 21 Oct 2015 19:39:57 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[MWD - Depth Tracking]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>
		<category><![CDATA[tip]]></category>
		<category><![CDATA[troubleshooting]]></category>
		<category><![CDATA[tutorial]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=1500</guid>
		<description><![CDATA[<p>&#160; Download as Document Mezintel Depth Tracker streams out ASCII data every 4 seconds via a 9-pin RS-232 male serial port. This data is in WITS format. WITS (Wellsite Information Transfer Specification) is a 20 year old worldwide oil and gas industry standard that specifies how to format text-based (ASCII) drilling data for transmission between [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/wits-format-mezintel-mwd/">WITS Format as used by Mezintel MWD Products</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/wits-format-mezintel-mwd/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Mezintel exhibiting at the Global Petroleum Show</title>
		<link>https://www.mezintel.com/blog/mezintel-exhibition-gps-2015/</link>
		<comments>https://www.mezintel.com/blog/mezintel-exhibition-gps-2015/#comments</comments>
		<pubDate>Thu, 04 Jun 2015 17:26:58 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[About Mezintel]]></category>
		<category><![CDATA[MWD - Depth Tracking]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>
		<category><![CDATA[events]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=1397</guid>
		<description><![CDATA[<p>Will you be at the Global Petroleum Show? Join Mezintel at one of the world&#8217;s largest oil &#38; gas shows! Come and chat with us at Booth 5209 in the lower level of the Big Four. We will be showing all of our directional drilling products. Want to attend for FREE? Join 60,000 visitors to [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/mezintel-exhibition-gps-2015/">Mezintel exhibiting at the Global Petroleum Show</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/mezintel-exhibition-gps-2015/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>New Large Indicators &amp; Plot on Depth Tracker</title>
		<link>https://www.mezintel.com/blog/large-gui-depth-tracker/</link>
		<comments>https://www.mezintel.com/blog/large-gui-depth-tracker/#comments</comments>
		<pubDate>Fri, 13 Dec 2013 16:31:22 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[Latest Features]]></category>
		<category><![CDATA[MWD - Depth Tracking]]></category>
		<category><![CDATA[updates]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=125</guid>
		<description><![CDATA[<p>One of our customers wanted larger indicators on the Mezintel Depth Tracker so that MWD operators can see depth status from 15 feet away. So, we added an alternative view that enlarges the block height, bit depth, ROP, hook load, hole depth, and slips status. Simply tap on the Samples button to use this enlarged [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/large-gui-depth-tracker/">New Large Indicators &#038; Plot on Depth Tracker</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/large-gui-depth-tracker/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Run Program as Administrator</title>
		<link>https://www.mezintel.com/blog/run-as-administrator/</link>
		<comments>https://www.mezintel.com/blog/run-as-administrator/#comments</comments>
		<pubDate>Tue, 10 Dec 2013 04:21:24 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[Construction Materials Testing]]></category>
		<category><![CDATA[MWD - Depth Tracking]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>
		<category><![CDATA[technical support]]></category>
		<category><![CDATA[tip]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=59</guid>
		<description><![CDATA[<p>In order to successfully run a Mezintel program, you must run it as administrator. Mezintel software that is not running as administrator will encounter errors as some point of being used. If the UAC dialog does not pop up when you try to run a Mezintel program, then it is not set to run as [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/run-as-administrator/">Run Program as Administrator</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/run-as-administrator/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
