<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Blog :: Mezintel Inc. - Measurements Intelligence &#187; Latest Features</title>
	<atom:link href="https://www.mezintel.com/blog/category/mwd-gamma/mg-new-features/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.mezintel.com/blog</link>
	<description></description>
	<lastBuildDate>Mon, 26 May 2025 17:05:38 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.5.2</generator>
		<item>
		<title>MWD Communication via Ethernet or Serial Port</title>
		<link>https://www.mezintel.com/blog/mwd-logging-via-ethernet-or-serial-port/</link>
		<comments>https://www.mezintel.com/blog/mwd-logging-via-ethernet-or-serial-port/#comments</comments>
		<pubDate>Fri, 09 Aug 2019 19:00:03 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[Latest Features]]></category>
		<category><![CDATA[MWD - Depth Tracking]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>
		<category><![CDATA[communication]]></category>
		<category><![CDATA[depth]]></category>
		<category><![CDATA[serial port]]></category>
		<category><![CDATA[tip]]></category>
		<category><![CDATA[v. 22.15.127]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=2909</guid>
		<description><![CDATA[<p>You can connect Mezintel Gamma to EDR depth tracking systems or MWD decoding systems via two modes: Serial Port (i.e. COM Port Number &#038; Baud Rate) Ethernet (i.e. IP Address and Telnet Port Number) These two methods are made available to guarantee that a PC running Mezintel Gamma LWD/MWD software (version 22.15.127 onwards), can connect [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/mwd-logging-via-ethernet-or-serial-port/">MWD Communication via Ethernet or Serial Port</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/mwd-logging-via-ethernet-or-serial-port/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Deriving Conductivity from Resistivity In Mezintel Gamma</title>
		<link>https://www.mezintel.com/blog/deriving-conductivity-resistivity/</link>
		<comments>https://www.mezintel.com/blog/deriving-conductivity-resistivity/#comments</comments>
		<pubDate>Sun, 04 Aug 2019 12:46:28 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[Latest Features]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>
		<category><![CDATA[LAS]]></category>
		<category><![CDATA[logging]]></category>
		<category><![CDATA[resistivity]]></category>
		<category><![CDATA[tip]]></category>
		<category><![CDATA[v. 22.87.128]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=2840</guid>
		<description><![CDATA[<p>The screenshot below shows how to setup this feature in Mezintel Gamma (as of version 22.87.128). Note that if you want to get just one Conductivity channel you will just fill in: GV4,1000 The first entry is the channel &#8216;Tag name&#8217; from which conductivity will be derived from, and the second number is the multiplier. [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/deriving-conductivity-resistivity/">Deriving Conductivity from Resistivity In Mezintel Gamma</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/deriving-conductivity-resistivity/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>UPDATE: IFR Surveys Correction for MWD</title>
		<link>https://www.mezintel.com/blog/ifr-surveys-improved/</link>
		<comments>https://www.mezintel.com/blog/ifr-surveys-improved/#comments</comments>
		<pubDate>Thu, 06 Jun 2019 23:26:56 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[Latest Features]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>
		<category><![CDATA[ifr]]></category>
		<category><![CDATA[surveys]]></category>
		<category><![CDATA[tip]]></category>
		<category><![CDATA[updates]]></category>
		<category><![CDATA[v.22.20.129]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=2790</guid>
		<description><![CDATA[<p>Recommended: First read a brief background and the benefits of handling IFR surveys in Mezintel Gamma. Exporting surveys for IFR correction is now even simpler in Mezintel Gamma. As of version 22.20.129, an IFR Express Export feature combines 3 steps of the export process into one: Mark survey row as MWD survey Duplicate the MWD [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/ifr-surveys-improved/"><strong>UPDATE:</strong> IFR Surveys Correction for MWD</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/ifr-surveys-improved/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>IFR Surveys Correction for MWD</title>
		<link>https://www.mezintel.com/blog/ifr-surveys/</link>
		<comments>https://www.mezintel.com/blog/ifr-surveys/#comments</comments>
		<pubDate>Thu, 20 Dec 2018 17:20:38 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[Latest Features]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>
		<category><![CDATA[ifr]]></category>
		<category><![CDATA[in-field]]></category>
		<category><![CDATA[surveys]]></category>
		<category><![CDATA[tips]]></category>
		<category><![CDATA[updates]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=2629</guid>
		<description><![CDATA[<p>Processing Surveys for IFR Corrections. Specialized third-party companies perform the actual IFR correction, while Mezintel Gamma recognizes and records the corrected surveys to produce appropriate reports. In handling IFR requirements in Mezintel Gamma, you can&#8230; Export a selection of surveys for IFR correction. (See instructions below) Manage both MWD surveys and their IFR-corrected equivalents. Switch [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/ifr-surveys/">IFR Surveys Correction for MWD</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/ifr-surveys/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Finding &#8216;Check Survey&#8217; Spots</title>
		<link>https://www.mezintel.com/blog/finding-check-surveys/</link>
		<comments>https://www.mezintel.com/blog/finding-check-surveys/#comments</comments>
		<pubDate>Fri, 19 Oct 2018 17:15:53 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[Latest Features]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>
		<category><![CDATA[saving time]]></category>
		<category><![CDATA[surveys]]></category>
		<category><![CDATA[tip]]></category>
		<category><![CDATA[updates]]></category>
		<category><![CDATA[v. 22.98.128]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=2573</guid>
		<description><![CDATA[<p>MWD operators often need to match surveys to particular points in a run. A common example of this is during &#8216;check survey&#8217;, which is recommended to be done near the last MWD survey on the previous run. For check survey, finding the last survey on the previous run is fairly straightforward since that survey is [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/finding-check-surveys/">Finding &#8216;Check Survey&#8217; Spots</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/finding-check-surveys/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>New Tools and Features For ECD Calculation</title>
		<link>https://www.mezintel.com/blog/new-tools-features-ecd-calculation/</link>
		<comments>https://www.mezintel.com/blog/new-tools-features-ecd-calculation/#comments</comments>
		<pubDate>Mon, 02 Oct 2017 16:10:41 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[Latest Features]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=2295</guid>
		<description><![CDATA[<p>Mezintel Gamma has new tools and features for ECD Calculation! Illustrated below, are the new features and tools to help you get the job done: Tool to Hand Bomb Values into the Software This new tool will allow you to generate the exact values that you need to show in the Mezintel Gamma program. This [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/new-tools-features-ecd-calculation/">New Tools and Features For ECD Calculation</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/new-tools-features-ecd-calculation/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Unattended Auto-Printing and Emailing of Complete Directional Drilling Report Collection</title>
		<link>https://www.mezintel.com/blog/auto-emailing-predefined-mwd-reports/</link>
		<comments>https://www.mezintel.com/blog/auto-emailing-predefined-mwd-reports/#comments</comments>
		<pubDate>Tue, 29 Aug 2017 22:16:23 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[Latest Features]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>
		<category><![CDATA[automation]]></category>
		<category><![CDATA[customer service]]></category>
		<category><![CDATA[email]]></category>
		<category><![CDATA[printing]]></category>
		<category><![CDATA[v. 22.33.128]]></category>
		<category><![CDATA[well logs]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=2186</guid>
		<description><![CDATA[<p>Mezintel Gamma can automatically generate and email predefined MWD reports &#8212; a collection that includes Survey reports (TXT, CSV, XLS files) LAS reports, and Log plots (PDF and TIFF). &#160; Download Brochure There&#8217;s no extra charge to use this automated reporting feature. Simply upgrade to the latest version of Mezintel Gamma, and find the feature [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/auto-emailing-predefined-mwd-reports/">Unattended Auto-Printing and Emailing of Complete Directional Drilling Report Collection</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/auto-emailing-predefined-mwd-reports/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Preventing Bad Values from Being Saved</title>
		<link>https://www.mezintel.com/blog/filter-bad-values-while-logging/</link>
		<comments>https://www.mezintel.com/blog/filter-bad-values-while-logging/#comments</comments>
		<pubDate>Wed, 14 Dec 2016 23:55:52 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[Latest Features]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>
		<category><![CDATA[updates]]></category>
		<category><![CDATA[v. 22.17.127]]></category>
		<category><![CDATA[well logs]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=1701</guid>
		<description><![CDATA[<p>While drilling, you may not want to log bad values for a particular sample (e.g. points that are too high or too low). In Mezintel Gamma (version 22.17.127 [1]), you can filter out such unwanted values from being logged while drilling. To configure filter thresholds for a sample go into the job&#8217;s main window: On [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/filter-bad-values-while-logging/">Preventing Bad Values from Being Saved</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/filter-bad-values-while-logging/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Average ROP: How to Smoothen ROP Plot</title>
		<link>https://www.mezintel.com/blog/average-rop-plot/</link>
		<comments>https://www.mezintel.com/blog/average-rop-plot/#comments</comments>
		<pubDate>Mon, 10 Aug 2015 18:50:32 +0000</pubDate>
		<dc:creator>Mezintel</dc:creator>
				<category><![CDATA[Latest Features]]></category>
		<category><![CDATA[MWD - Gamma Logging]]></category>
		<category><![CDATA[depth]]></category>
		<category><![CDATA[rop]]></category>
		<category><![CDATA[updates]]></category>
		<category><![CDATA[v.22.00.110]]></category>
		<category><![CDATA[well logs]]></category>

		<guid isPermaLink="false">http://www.mezintel.com/blog/?p=1621</guid>
		<description><![CDATA[<p>In drilling, there are two are two main ways to interpret the rate of penetration (ROP): Instantaneous and Average. Here are good definitions of the two: Instantaneous ROP is measured over a finite time or distance, while drilling is still in progress. It gives a snapshot perspective of how a particular formation is being drilled [...]</p>
<p>The post <a rel="nofollow" href="https://www.mezintel.com/blog/average-rop-plot/">Average ROP: How to Smoothen ROP Plot</a> appeared first on <a rel="nofollow" href="https://www.mezintel.com/blog">Blog :: Mezintel Inc. - Measurements Intelligence</a>.</p>
]]></description>
		<wfw:commentRss>https://www.mezintel.com/blog/average-rop-plot/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
